August 2025 batch: 3 AUS 32 parameters verified — SGS report 0594

SGS laboratory report 2508250594: 3 ISO 22241-1 parameters measured on the August 2025 batch of AdBlue® By Madin, all within limits.

SGS Vietnam measured 3 of the ISO 22241-1 parameters for AUS 32 on the August 2025 production batch; all 3 came back inside their limits. Report 2508250594, issued 22/08/2025.

Report details

  • Laboratory: SGS Vietnam Ltd., Ho Chi Minh City
  • Report number: 2508250594
  • Job / sample number: 2021396 (NR25-1.02227-1)
  • Sample: Aus32 – Batch No.: MADIN ADBLUE – 0825 Ngày 11/08/2025
  • Sample received: 19/08/2025
  • Testing period: 20 to 22 Aug. 2025
  • Report issued: 22/08/2025

Measured results

#ParameterMethodResultUnitLimit
1Density at 20°CISO 12185:20241089.3kg/m3min 1087.0 / max 1093.0
2Urea contentISO 22241-2:201932.2%wtmin 31.8 / max 33.2
3Refractive index at 20°C1.3826min 1.3814 / max 1.3842

What these numbers mean

Urea content and density fix the concentration. AUS 32 is 32.5% urea by weight and an SCR system doses on that assumption: too weak and NOx conversion falls short, too strong and urea crystallises in the injector.

Biuret forms when urea is overheated during manufacture. It will not convert to ammonia and it deposits in the dosing line, which is why the limit is a tight 0.3%.

Metals — calcium, iron, copper, zinc, chromium, nickel, aluminium, magnesium, sodium and potassium — poison the SCR catalyst permanently, so limits sit at 0.2–0.5 mg/kg. “N.D” means not detected above the laboratory’s 0.03 mg/kg detection limit.

Insoluble matter and phosphate block the injector and coat the catalyst; aldehyde and alkalinity flag contamination of the urea feedstock.

About the standard

AUS 32 (Aqueous Urea Solution 32.5%) is defined by ISO 22241-1. AdBlue® is the registered trademark of the German Association of the Automotive Industry (VDA) for fluid meeting that specification. Madin holds a VDA licence to use the AdBlue® trademark (certificate 0005431, valid to 16 October 2028) and is certified to ISO 9001:2015 for the manufacture and supply of aqueous urea solution (certificate 22/17582, valid to 10 October 2028).

The limit column above is the specification supplied to the laboratory; SGS notes on each report that limits are based on the client’s specification. Urea content is measured to ISO 22241-2:2019 and density to ISO 12185:1996.

The report itself

The full SGS document, exactly as issued – all three pages, including the laboratory’s remarks and the photograph of the sample as received.

Download the SGS report 2508250594 (PDF, 699 KB)